Industry · colocation & multi-tenant IDC
Colocation & multi-tenant IDC
One cabinet, one tenant boundary. One row, one billable unit.
A tenant does not rent a room. They rent a cabinet, and what they can point at is the door, the meter and the row they are allowed to grow into. That is what this page prices.
Send us your row layout
- Cabinets per row
- 3–8
- Deployment
- 2–3weeks
- Cooling energy saved
- 25%+
The open row problem
What an open row shares, and what a tenant block does not
Four things a colocation operator has to answer for. Each one is a build decision, not an adjective.
Open rowCold air mixes with hot air along the whole run, so the last cabinet in the row sets the supply temperature for everyone.
Tenant blockContained cold aisle with blanking panels, so the supply air reaches the intake of every cabinet in that row.
Open rowOne shared run of cabinets with no line a tenant can point at when he asks where his equipment ends.
Tenant blockA front door and a rear door on every cabinet, so the boundary is a physical object, not a floor plan.
Open rowOne meter for the whole row, and an argument every month about who drew what.
Tenant blockMounting positions reserved for intelligent busway / PDU inside each cabinet — third-party metering, per cabinet.
Open rowAdding capacity disturbs the whole row, so it gets postponed until a tenant complains.
Tenant blockThree to eight cabinets side by side, extendable, added tenant by tenant without touching the row next door.
Specification
What a tenant boundary is made of
| Parameter (per cabinet) | Value |
|---|---|
| Rack height | 42U = 2000 mm · 47U = 2200 mm; other heights built to order |
| Width × depth | 600×1000 · 600×1100 · 600×1200 · 800×1200 mm |
| Uprights / doors | 2.0 mm uprights · 1.2 mm doors |
| Steel | Baosteel / Ansteel SPCC cold-rolled |
| Front door mesh | ≥75% |
| Rear door mesh | ≥60% |
| Static load | 1,000 kg standard · 1,500 kg on reinforced-frame models |
| Grounding | Front door, rear door and frame — multiple points |
| Metering positions | Mounting positions reserved for intelligent busway / PDU — third-party metering, per cabinet |
| Cable space | 600 mm depth for patch and power; 800 mm wide for high cable count |
| Surface finish | Degrease → phosphating → electrostatic powder coating |
| Structural warranty | 5 years on the rack frame |
| Containment per row | 3–8 cabinets side by side, extendable; sliding glass doors at the row end; flip top panels for gas suppression access |
Row elevation
Let the next row happen on paper first
The elevation below is the row you are buying, drawn end-on: cabinets side by side, sliding glass doors at the row end, flip top panels above the aisle, an in-row cooling unit, and blanking positions where cabinets are not yet filled.
- Row endSliding glass doors close the aisle; the row reads as one room.
- RoofFlip top panels, so gas suppression can reach the aisle.
- CoolingIn-row unit closes the cooling loop with the containment.
- BlankingEmpty U positions are covered, not left open.
Deployment cadence
Five steps, and only two dates in the whole page
-
01
Site survey and floor check
-
02
Row layout and specification freeze
-
03
Factory build
-
04
Containment, doors and blind panels
-
05
Power-up and handover
A contained row is deployed in 2–3 weeks. A single-row cabinet is installed in 3 hours.
Scope of supply
What comes from us, and what comes from a partner brand
Machined and assembled by ems-rack
- Server racks42U and 47U, 600 and 800 wide.
- Cold aisle containmentRoof panels, end doors and blind panels for the row.
- Micro-modular roomsContainment, in-row cooling and power as one delivered row.
- Power distribution cabinetsSheet-metal enclosures with the reserved zone for busway or PDU.
Partner brands, supplied under authorisation
- Precision air conditioningEnvicool. Manufactured by Envicool — not by ems-rack.
- UPSBainard. Manufactured by Bainard — not by ems-rack.
- Structured cablingYizhou. Manufactured by Yizhou — not by ems-rack.
Project record
Taiyuan No. 4 Hospital data centre — healthcare
This is a hospital project, and it is labelled as one: the client is a healthcare operator, not a colocation provider. It is on this page because the delivery mechanism is the one a colocation expansion needs.
- Scope
- Micro-modular room, precision air conditioning and environmental monitoring.
- Method
- Prefabricated in the factory and delivered whole, so on-site work was cut down rather than spread out.
- Outcome
- Accepted in a single inspection.
Next step
Send us the row you want to add
Row layout, tenant count and the power you want at each cabinet — we answer with a bill of materials per row.
Every request is either accepted or explicitly refused — never silently dropped.